Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2017-05-26-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208714
DEA: 08043514
EFIS: 0800000010
DIST-CO-RTE-PM08-SBD-58-R22.2/R31.1
Award Date12/30/2014
Closeout Date08/29/2018
Work DescriptionREALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY
Location DescriptionHINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD.
QA Service Level1 (Verified on 03/22/2013)

Sample Information

Sample Taken Date05/26/2017 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/30/2017
Sample typeQuality Assurance A brief description of the sample6X12
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byROBERT Last name of sampler or witnessed byBERSBACH
Title of samplerTECH Telephone number of samplerUnknown
Laboratory sample identification915-526 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameROBERTSONS Transportation Laboratory (TL) Number20170526
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierSR58 EXPRESS WAY AT HINKLEY
Structure nameRW 1633 STEM WALL POUR 6

Material Information

Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collected1226 The batch plant ticket number from where the sample was collected2267153
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedRW 1633 STEM POUR 6 Where the material sample would have been placed if not sampledRW 1633 STEM WALL POUR 6
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-05-26-5-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/30/2017Matthew Clayton
Yes
06/06/2017
2017-05-26-5-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/31/2017Matthew Clayton
Yes
05/31/2017
2017-05-26-5-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory06/02/2017Matthew Clayton
Yes
06/05/2017
2017-05-26-5-4ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory06/23/2017Matthew Clayton
Yes
06/23/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-05-26-5-1 ASTM C39-17a (Verified)
DIME Test ID: 2017-05-26-5-2 ASTM C39-17a (Verified)
DIME Test ID: 2017-05-26-5-3 ASTM C39-17a (Verified)
DIME Test ID: 2017-05-26-5-4 ASTM C39-17a (Verified)