Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-05-23-2
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 211777 DEA: 04209504 EFIS: 0412000116 |
DIST-CO-RTE-PM | 04-MRN,SON-1-50.2/50.5,0.0/0.2 |
Award Date | 01/04/2017 |
Closeout Date | 10/21/2019 |
Work Description | REPLACE ESTERO BRIDGE AND REALIGN APPROACHING ROADWAY; Bridge No. 27-0121 |
Location Description | MARIN AND SONOMA COUNTIES NEAR VALLEY FORD FROM 0.4 MILE SOUTH OF ESTERO AMERICANO BRIDGE TO 0.2 MILE NORTH OF ESTERO AMERICANO BRIDGE |
QA Service Level | 1 (Verified on 01/17/2017) |
Sample Information
Sample Taken Date | 05/23/2017 |
Sample Unique Key | 2 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 05/24/2017 |
Sample type | Acceptance |
A brief description of the sample | A449 Bolt, Nut, Washer. |
The quantity of what the sample constitutes | 3 |
From where was the sample collected | Distributor |
First name of sampler or witnessed by | Greg |
Last name of sampler or witnessed by | Thompson |
Title of sampler | Unknown |
Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown |
Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | R D Fastener |
Transportation Laboratory (TL) Number | C741427 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-019-17 |
Structure unique identifier | Not set |
Structure name | Not set |
---|
Material Information
Material Type | SMTL TM3 - Fastener Assembly |
Rocap Number(s) | |
Heat Number(s) | |
Nut Mfg. Lot Number(s) | 369676A |
Washer Mfg. Lot Number(s) | 298421 |
Bolt Specification | A449 |
Bolt Length(s) | 17.5 |
Nut Specification | A563 |
Washer Specification | F436 |
Finish | HDG |
Diameter/Size | 0.875 |
Bolt Mfg. Lot Number | 74281/1 |
Rocap Test Requirement(s) | |
Lubricant Requirements(s) | |
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2017-05-23-2-1 | ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
2017-05-23-2-2 | ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
2017-05-23-2-3 | ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
2017-05-23-2-4 | ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
2017-05-23-2-5 | ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
2017-05-23-2-6 | ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
2017-05-23-2-7 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
2017-05-23-2-8 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
2017-05-23-2-9 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
2017-05-23-2-10 | ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | Arnold Viken | CT HQ - Sacramento Structural Materials Testing Laboratory | 05/24/2017 | Arnold Viken | Yes | 06/02/2017 | | |
26842268432684426845268462684726848268492685026851