Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-05-09-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210963
DEA: 120N78U4
EFIS: 1215000036
DIST-CO-RTE-PM12-ORA-5,22,57,73,133,405,etc.-VARIOUS
Award Date03/08/2016
Closeout Date06/21/2021
Work DescriptionINSTALL HD CCTVS AND MODIFY COMMUNICATION SYSTEM.
Location DescriptionINSTALL HD CCTVS AND MODIFY COMMUNICATION SYSTEM.
QA Service Level1 (Verified on 08/15/2016)

Sample Information

Sample Taken Date05/09/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/11/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byGray
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) NumberC720069
Inspector Lot Number from the Transportation Laboratory (TL) FormS3203217 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4049973
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-05-09-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/11/2017Fred
Yes
05/19/2017Bar Broke; OK Necking
2017-05-09-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/11/2017Fred
Yes
05/19/2017Bar Broke; OK Necking
2017-05-09-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/11/2017Fred
Yes
05/19/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-05-09-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-05-09-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-05-09-7-3 CTM 670-December 2013 (Verified)