Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-03-24-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211508
DEA: 080R1304
EFIS: 0812000027
DIST-CO-RTE-PM08-SBD-62-16.8/25.2
Award Date11/09/2016
Closeout Date08/21/2018
Work DescriptionINSTALL TWO-WAY LEFT TURN LANES AND WIDEN SHOULDER
Location DescriptionSAN BERNARDINO COUNTY IN JOSHUA TREE AND NEAR TWENTY NINE PALMS AT VARIOUS LOCATIONS FROM 0.1 MILE EAST OF SHERWOOD ROAD TO 0.1 MILE EAST OF LEE DRIVE
QA Service Level1 (Verified on 09/21/2016)

Sample Information

Sample Taken Date03/24/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/29/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) NumberC953700
Inspector Lot Number from the Transportation Laboratory (TL) FormL5306617 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)4049973
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerTNT Rebar
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-03-24-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/2017Brian
Yes
04/06/2017Bar Broke; OK Necking
2017-03-24-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/2017Brian
Yes
04/06/2017Bar Broke at Weld
2017-03-24-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/2017Brian
Yes
04/06/2017Bar Broke; OK Necking
2017-03-24-4-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/30/2017Brian
Yes
04/06/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-03-24-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-03-24-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-03-24-4-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-03-24-4-4 CTM 670-December 2013 (Verified)