Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-02-03-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211619
DEA: 101G6404
EFIS: 1017000012
DIST-CO-RTE-PM10-SJ-26-11.0, 1.10
Award DateNot set
Closeout Date03/22/2023
Work Descriptionrepair bridge after truck hit
Location DescriptionNot set
QA Service Level1 (Verified on 10/20/2016)

Sample Information

Sample Taken Date02/03/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/03/2017
Sample typeQuality Assurance A brief description of the sampleBar Lock Coupler
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byChau Last name of sampler or witnessed byHu
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCamblin Steel Transportation Laboratory (TL) NumberC749403
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau CMC
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size6 Coupler ModelBar Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)73101028 Rebar Heat Number(s)65025990 4062826
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-02-03-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/08/2017Brian
Yes
02/15/2017Service Splice
2017-02-03-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/08/2017Brian
Yes
02/15/2017Service Splice
2017-02-03-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/08/2017Brian
Yes
02/15/2017Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-02-03-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-02-03-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-02-03-2-3 CTM 670-December 2013 (Verified)