Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-01-26-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211523
DEA: 120N6804
EFIS: 1214000083
DIST-CO-RTE-PM12-ORA-72-11.9
Award Date08/16/2016
Closeout Date08/28/2017
Work DescriptionMODIFY SIGNALS, ADD SAFETY LIGHTING, UPDATE CURB RAMPS.
Location DescriptionORANGE COUNTY IN LA HABRA AND WHITTIER AT VALLEY HOME AVENUE
QA Service Level1 (Verified on 09/06/2016)

Sample Information

Sample Taken Date01/26/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/30/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byDave Last name of sampler or witnessed byWeeks
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) NumberC953662
Inspector Lot Number from the Transportation Laboratory (TL) FormL7901617 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)4049973
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerTNT
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-01-26-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/2017Brian
Yes
02/07/2017Bar Broke in Heat Affected Area
2017-01-26-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/2017Brian
Yes
02/07/2017Bar Broke in Heat Affected area
2017-01-26-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/2017Brian
Yes
02/07/2017Bar Broke in Heat Affected Area
2017-01-26-7-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/2017Brian
Yes
02/07/2017Bar Broke in Heat Affected Area

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-01-26-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-26-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-26-7-3 CTM 670-December 2013 (Verified)