Sample Record

DIME Sample ID 2024-05-06-26

Project Information

Project IdentifiersProject ID: 209820
DEA: 04297634
EFIS: 0415000040
COOP: 042548
DIST-CO-RTE-PM04-ALA-84,680-17.9/21
Award Date02/19/2021
Closeout DateNot set
Work DescriptionROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location DescriptionALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
QA Service Level1 (Verified on 11/04/2019)

Owner Lab

  • Harper Precast

Sample Information

Sample Taken Date05/06/2024 Sample Unique Key26
Date that the sample was received by the laboratory/organization performing the testing05/07/2024 Sample typeQuality Control
A brief description of the sampleMSE Wall Panels The quantity of what the sample constitutes6 yds
From where was the sample collectedFabricator First name of sampler or witnessed byRobert
Last name of sampler or witnessed byWinters Title of samplerQCM
Telephone number of sampler8015143968 Laboratory sample identificationHarper Precast Lab
Linked DIME Sample ID The fabricator/manufacturer/facility nameHarper Precast
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number753030
The truck number from where the sample was collected40 The batch plant ticket number from where the sample was collected109289
Concrete batch plantHarper Ready Mix The fabricator/manufacturer designation for the sampleCA-49
A detailed description of where the material sample was collectedMiddle third of batch from truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-05-06-26-1ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure MethodRobert Winters, Harper Precast05/06/202405/08/2024
No
Air was low for mix but project does not require air entrainment.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-05-06-26-1 ASTM C231-17a