Sample Record
Owner Lab
- Harper Precast
DIME Sample ID 2024-05-06-26
Project Information
Project Identifiers | Project ID: 209820 DEA: 04297634 EFIS: 0415000040 COOP: 042548 |
---|---|
DIST-CO-RTE-PM | 04-ALA-84,680-17.9/21 |
Award Date | 02/19/2021 |
Closeout Date | Not set |
Work Description | ROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION. |
Location Description | ALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84 |
QA Service Level | 1 (Verified on 11/04/2019) |
Sample Information
Sample Taken Date | 05/06/2024 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/07/2024 |
Sample type | Quality Control | A brief description of the sample | MSE Wall Panels |
The quantity of what the sample constitutes | 6 yds | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Robert | Last name of sampler or witnessed by | Winters |
Title of sampler | QCM | Telephone number of sampler | 8015143968 |
Laboratory sample identification | Harper Precast Lab | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Harper Precast | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 753030 |
---|---|---|---|
The truck number from where the sample was collected | 40 | The batch plant ticket number from where the sample was collected | 109289 |
Concrete batch plant | Harper Ready Mix | The fabricator/manufacturer designation for the sample | CA-49 |
A detailed description of where the material sample was collected | Middle third of batch from truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2024-05-06-26-1 | ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method | Robert Winters, Harper Precast | 05/06/2024 | Robert Winters | No | Air was low for mix but project does not require air entrainment. | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2024-05-06-26-1 ASTM C231-17a