Sample Record
DIME Sample ID 2024-03-30-1
Project Information
| Project Identifiers | Project ID: 994116 DEA: 010J4104 EFIS: 0119000025 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-299-30.7/33.4 |
| Award Date | 11/23/2022 |
| Closeout Date | Not set |
| Work Description | Project Name: HUM-299 Curve Improvement |
| Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE |
| QA Service Level | 1 (Verified on 07/29/2022) |
Owner Lab
- SHN Engineers & Geologists, Incorporated
Sample Information
| Sample Taken Date | 03/30/2024 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/31/2024 | Sample type | Quality Assurance |
| A brief description of the sample | E675WRF | The quantity of what the sample constitutes | 150 Cy |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Zack |
| Last name of sampler or witnessed by | Arnold | Title of sampler | special inspector |
| Telephone number of sampler | 707-441-8855 | Laboratory sample identification | C9134 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Eureka Ready Mix Alton | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | E675WRF |
|---|---|---|---|
| The truck number from where the sample was collected | 94 | The batch plant ticket number from where the sample was collected | 35021 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | Mix | |
| A detailed description of where the material sample was collected | Concrete sample from wheelbarrow | Where the material sample would have been placed if not sampled | Slab |
| From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-03-30-1-1 ASTM C231-17a (Verified)
DIME Test ID: 2024-03-30-1-2 ASTM C1064-17 (Verified)
DIME Test ID: 2024-03-30-1-3 ASTM C143-20 (Verified)
DIME Test ID: 2024-03-30-1-4 ASTM C138-17a (Verified)
DIME Test ID: 2024-03-30-1-5 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-03-30-1-6 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-03-30-1-7 CTM 521-June 2020 (Verified)