Sample Record

DIME Sample ID 2016-08-15-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210040
DEA: 04297624
EFIS: 0400020581
COOP: 042558
DIST-CO-RTE-PM04-ALA-84-22.9/25.7
Award Date09/30/2015
Closeout Date03/12/2020
Work DescriptionWIDENING AND EXPRESSWAY UPGRADES
Location DescriptionON ROUTE 84, FROM RUBY HILL DRIVE TO NORTH OF CONCANNON BOULEVARD
QA Service Level1 (Verified on 11/10/2015)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/15/2016 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing08/18/2016 Sample typeQuality Assurance
A brief description of the sampleService Splice Couplers The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byOscar
Last name of sampler or witnessed bySantos Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHarris Rebar
Transportation Laboratory (TL) Number920778 Inspector Lot Number from the Transportation Laboratory (TL) FormN/A
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size11 Coupler ModelBar Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)492018 Rebar Heat Number(s)SE15104964
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-08-15-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/24/201608/24/2016
Yes
08/24/2016Service SplicePublic - Test Data Visible
2016-08-15-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/24/201608/24/2016
Yes
08/24/2016Service SplicePublic - Test Data Visible
2016-08-15-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/24/201608/24/2016
Yes
08/24/2016Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-08-15-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-15-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-15-5-3 CTM 670-December 2013 (Verified)