Sample Record

DIME Sample ID 2024-03-25-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994574
DEA: 050C7334
EFIS: 0518000116
DIST-CO-RTE-PM05-SCR-1-10.5/13.4
Award Date06/29/2023
Closeout DateNot set
Work DescriptionCONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/13/2023)

Owner Lab

  • CT HQ - QASI Bay Area Field Office

Sample Information

Sample Taken Date03/25/2024 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing03/25/2024 Sample typeAuthorization
A brief description of the sampleASTM A615 Gr 75 bar The quantity of what the sample constitutes1 Lot
From where was the sample collectedSupplier First name of sampler or witnessed byRyan
Last name of sampler or witnessed byParr Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameZ Systems
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB373-027-24
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size#9
Nut Specification for Threaded BarASTM A897 System ManufacturerZ Systems
Epoxy Coating ColorNA Threaded Bar ApplicationSoil Nail
Coating StandardsUncoated Bar Heat Number(s)A216934
Nut Heat Number(s)L193 Bar Lot Number
Nut Lot Number Coupler Heat Number(s)
Coupler Grade

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-03-25-1-1ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory03/26/202403/26/2024
Yes
03/27/2024A615 Bar and NutPublic - Test Data Visible
2024-03-25-1-2ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory03/26/202403/26/2024
Yes
03/27/2024A615 Bar and NutPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-03-25-1-1 ASTM A615-20 (Verified)