Sample Record
DIME Sample ID 2024-01-18-3
Project Information
| Project Identifiers | Project ID: 215620 DEA: 01436404 EFIS: 0100000193 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-101-35.8/36.5 |
| Award Date | 07/11/2022 |
| Closeout Date | Not set |
| Work Description | Dr. Fine Bridge Replacement |
| Location Description | DR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER. |
| QA Service Level | 1 (Verified on 03/26/2021) |
Owner Lab
- CT D01 - Crescent City Field Laboratory
Sample Information
| Sample Taken Date | 01/18/2024 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/22/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | 3 cy |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Joshua |
| Last name of sampler or witnessed by | Erler | Title of sampler | ASR |
| Telephone number of sampler | 7074985107 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Tidewater Starry pit | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SR Minor Structure |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 58966 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Detour Abutment 6 | Where the material sample would have been placed if not sampled | Transition block |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2024-01-18-3-1 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | Joshua Erler, CT D01 - Crescent City Field Laboratory | 02/01/2024 | 02/01/2024 | No | 14 Day break Transition blocks |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-01-18-3-1 CTM 521-June 2020
