Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2023-11-14-57
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
| Award Date | 06/06/2018 |
| Closeout Date | Not set |
| Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
| Location Description | LA/SBD County Line to PM 13.2 near I-15 |
| QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
| Sample Taken Date | 11/14/2023 | Sample Unique Key | 57 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/29/2023 |
| Sample type | Verification | A brief description of the sample | #6 Epoxy Coated Rebar |
| The quantity of what the sample constitutes | AD Audit | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Cattabiani |
| Title of sampler | AMR | Telephone number of sampler | 201-674-6612 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Fletcher Coating | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 251423 |
|---|---|---|---|
| Rebar Epoxy Batch Number(s) | 3K11 | Rebar Coating Specification | ASTM A934 |
| Rebar Size (#) | 6 | Rebar Coating Color | Purple |
| Rebar Manufacturer | Cascade Steel | Rebar Coater | Fletcher Coating Company |
| Rebar Powder Manufacturer | Release Number | ||
| Quality Assurance Code |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-11-14-57-2 ASTM A934-19 (Verified)
DIME Test ID: 2023-11-14-57-3 ASTM A934-19 (Verified)