Sample Record

DIME Sample ID 2023-10-27-43

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Owner Lab

  • G3 Quality, Incorporated - Cerritos

Sample Information

Sample Taken Date10/27/2023 Sample Unique Key43
Date that the sample was received by the laboratory/organization performing the testing11/08/2023 Sample typePer Request
A brief description of the sample#4 HRC 500/510 The quantity of what the sample constitutes60
From where was the sample collectedJob Site First name of sampler or witnessed byRobert
Last name of sampler or witnessed byMendoza Title of samplerInspector
Telephone number of sampler(951) 264-7798 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameVineyard Deck Stage 2
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#4 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)1000217245N Rebar Heat Number(s)4130936
Rebar Size 2 Coupler Unique IDTP-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-10-27-43-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory11/13/202311/13/2023
Yes
11/13/2023Service Splice Public - Test Data Visible
2023-10-27-43-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory11/13/202311/13/2023
Yes
11/13/2023Service Splice Public - Test Data Visible
2023-10-27-43-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory11/13/202311/13/2023
Yes
11/13/2023Service Splice Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-10-27-43-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-10-27-43-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-10-27-43-3 CTM 670-December 2013 (Verified)