Sample Record

DIME Sample ID 2016-05-17-1

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout Date02/12/2025
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date05/17/2016 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing05/18/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes150
From where was the sample collectedJob Site First name of sampler or witnessed byKevin
Last name of sampler or witnessed byChurchill Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC Rbar
Transportation Laboratory (TL) NumberC952966 Inspector Lot Number from the Transportation Laboratory (TL) FormL0203316
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingRetest
Service or UltimateUltimate Rebar Heat Number(s)4054955
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop2'-1" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-05-17-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Bryan, CT HQ - Sacramento Structural Materials Testing Laboratory05/19/201605/19/2016
No
Bar Broke; OK Necking
2016-05-17-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Bryan, CT HQ - Sacramento Structural Materials Testing Laboratory05/19/201605/19/2016
No
Bar Broke; OK Necking
2016-05-17-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Bryan, CT HQ - Sacramento Structural Materials Testing Laboratory05/19/201605/19/2016
No
Bar Broke; OK Necking
2016-05-17-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Bryan, CT HQ - Sacramento Structural Materials Testing Laboratory05/19/201605/19/2016
No
Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-17-1-1 CTM 670-December 2013
DIME Test ID: 2016-05-17-1-2 CTM 670-December 2013
DIME Test ID: 2016-05-17-1-3 CTM 670-December 2013
DIME Test ID: 2016-05-17-1-4 CTM 670-December 2013