Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2023-05-09-6
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 215649 DEA: 043G4884 EFIS: 0412000088 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-92-R14.4/R18.8 |
| Award Date | 09/01/2022 |
| Closeout Date | 10/09/2024 |
| Work Description | CLEAN AND PAINT STEEL BRIDGE TOWERS, REPLACE HIGH STRENGTH BOLTS. |
| Location Description | SAN MATEO COUNTY IN FOSTER CITY FROM SAN MATEO-HAYWARD BRIDGE TO ALAMEDA COUNTY LINE |
| QA Service Level | 1 (Verified on 03/29/2021) |
Sample Information
| Sample Taken Date | 05/09/2023 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/18/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 1"x3-3/4" F3125 TC Bolts |
| The quantity of what the sample constitutes | 98 bolts | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dylan | Last name of sampler or witnessed by | LaRose |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Unytite, Inc. | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 10610610, 6214982404, 174314 | Nut Mfg. Lot Number(s) | 31083-6214982404 |
| Washer Mfg. Lot Number(s) | D6240 | Bolt Specification | F1852 A325TC |
| Bolt Length(s) | 3-3/4" | Nut Specification | A563 DH |
| Washer Specification | F436 | Finish | Mech Galv |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 30978-10610610 |
| Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-05-09-6-1 ASTM F606-21 (Verified)
DIME Test ID: 2023-05-09-6-2 ASTM F606-21 (Verified)
DIME Test ID: 2023-05-09-6-3 ASME B1.2-83r17 (Verified)
DIME Test ID: 2023-05-09-6-4 ASME B1.2-83r17 (Verified)
DIME Test ID: 2023-05-09-6-5 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-05-09-6-6 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-05-09-6-7 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-05-09-6-8 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-05-09-6-9 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-05-09-6-10 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-05-09-6-11 ASTM E18-20 (Verified)
DIME Test ID: 2023-05-09-6-12 ASTM E18-20 (Verified)