Sample Record
Owner Labs
- CT HQ - QASI Los Angeles Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2022-10-19-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 88887 DEA: PC-Barrier-STOCK EFIS: PC-Barrier-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for precast barrier rail stock material. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/19/2022 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/26/2022 |
| Sample type | Authorization | A brief description of the sample | Epoxy Coated ASTM A615 Grade 60 |
| The quantity of what the sample constitutes | 3200 EA | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 7073428602 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Fletcher Coating Co | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-113-22 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 072522 and 1201044760 |
|---|---|---|---|
| Rebar Epoxy Batch Number(s) | 2E03 | Rebar Coating Specification | ASTM A934 |
| Rebar Size (#) | #6 | Rebar Coating Color | Purple |
| Rebar Manufacturer | Cascade Steel and Nucor | Rebar Coater | Fletcher Coating Company |
| Rebar Powder Manufacturer | 3M | Release Number | #33114 |
| Quality Assurance Code | A93422J19R2S12E03 |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2022-10-19-2-1 ASTM A934-13 (Verified)
DIME Test ID: 2022-10-19-2-2 ASTM A934-13 (Verified)