Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2022-05-18-39

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date05/18/2022 Sample Unique Key39
Date that the sample was received by the laboratory/organization performing the testing06/20/2022 Sample typePer Request
A brief description of the sample#4 500/510 HRC Coupler The quantity of what the sample constitutes48
From where was the sample collectedJob Site First name of sampler or witnessed byRobert
Last name of sampler or witnessed byMendoza Title of samplerInspector
Telephone number of sampler(951) 264-7798 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameGrove EB Deck
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#4 Coupler Model500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)Heat 5391825-04 and NF14103419 Rebar Heat Number(s)4114043 and 4114916
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2022-05-18-39-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory06/27/202206/27/2022
Yes
06/28/2022ok neckingPublic - Test Data Visible
2022-05-18-39-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory06/27/202206/27/2022
Yes
06/28/2022ok neckingPublic - Test Data Visible
2022-05-18-39-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory06/27/202206/27/2022
Yes
06/28/2022ok neckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-05-18-39-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-05-18-39-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-05-18-39-3 CTM 670-December 2013 (Verified)