Sample Record
DIME Sample ID 2022-01-13-16
Project Information
| Project Identifiers | Project ID: 214993 DEA: 051F5004 EFIS: 0514000003 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101,135-70.6/71.2;0.1 |
| Award Date | 11/17/2020 |
| Closeout Date | 01/11/2024 |
| Work Description | CONSTRUCT CONCRETE BRIDGE, BRIDGE REMOVAL, COLD PLANE, PLACE HMA. |
| Location Description | SANTA BARBARA COUNTY AT LOS ALAMOS ON ROUTE 101 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 101/135 SEPARATION AND ON ROUTE 135 AT ROUTE 101/135 SEPARATION |
| QA Service Level | 1 (Verified on 09/03/2020) |
Owner Lab
- Kie-Con, Incorporated - Antioch
Sample Information
| Sample Taken Date | 01/13/2022 | Sample Unique Key | 16 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/14/2022 | Sample type | Quality Control |
| A brief description of the sample | 4x8 concrete cylinders | The quantity of what the sample constitutes | 58 CY |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Stephen |
| Last name of sampler or witnessed by | Haynes | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | KIE-CON, INC | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | K7010-705 CPO R3 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 113285 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | 20-138 1/13/22 | |
| A detailed description of where the material sample was collected | Concrete sample from wheelbarrow | Where the material sample would have been placed if not sampled | Box Girder |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2022-01-13-16-1 | ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete | Stephen Haynes, Kie-Con, Incorporated - Antioch | 01/13/2022 | No | |||||
| 2022-01-13-16-2 | ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete | Carl J. Ogden, Kie-Con, Incorporated - Antioch | 01/13/2022 | No | |||||
| 2022-01-13-16-3 | ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete | Jason Allen, Kie-Con, Incorporated - Antioch | 01/13/2022 | No | |||||
| 2022-01-13-16-4 | ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Jason Allen, Kie-Con, Incorporated - Antioch | 01/14/2022 | No | |||||
| 2022-01-13-16-5 | CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature) | Stephen Haynes, Kie-Con, Incorporated - Antioch | 02/01/2023 | No | |||||
| 2022-01-13-16-6 | CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature) | Stephen Haynes, Kie-Con, Incorporated - Antioch | 02/01/2023 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2022-01-13-16-1 ASTM C1064-17
DIME Test ID: 2022-01-13-16-2 ASTM C143-20
DIME Test ID: 2022-01-13-16-3 ASTM C138-17a
DIME Test ID: 2022-01-13-16-4 ASTM C39-18
DIME Test ID: 2022-01-13-16-5 CTM TEMP1-16
DIME Test ID: 2022-01-13-16-6 CTM TEMP1-16