Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2021-09-07-15
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
| Award Date | 06/06/2018 |
| Closeout Date | Not set |
| Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
| Location Description | LA/SBD County Line to PM 13.2 near I-15 |
| QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
| Sample Taken Date | 09/07/2021 | Sample Unique Key | 15 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/09/2021 | Sample type | Quality Assurance |
| A brief description of the sample | .6in Prestressing Strand | The quantity of what the sample constitutes | 10 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Don |
| Last name of sampler or witnessed by | Hiranaga | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Sumiden Wire | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | Number of Coils | ||
| Group Number | Strand Diameter | ||
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0578620, S0549821 | Mfg. Lot Number(s) | NA |
| Manufacturer(s) | Sumiden Wire |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-09-07-15-1 ASTM A416-15 (Verified)
DIME Test ID: 2021-09-07-15-2 ASTM A416-15 (Verified)
DIME Test ID: 2021-09-07-15-3 ASTM A416-15 (Verified)
DIME Test ID: 2021-09-07-15-4 ASTM A416-15 (Verified)