Sample Record

DIME Sample ID 2021-07-28-11

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Owner Lab

  • CT HQ - Sacramento Cement Testing Laboratory

Sample Information

Sample Taken Date07/28/2021 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing07/28/2021 Sample typeAnnual Source Testing
A brief description of the sampleType II/IV Portland Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM215158
Linked DIME Sample ID The fabricator/manufacturer/facility nameNational Cement
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandNational
MillLebec Type of Cementitious MaterialType II/V Cement

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2021-07-28-11-2ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Anthony Valdez, CT HQ - Sacramento Cement Testing Laboratory10/07/2021
Yes
11/04/20213 day test -- Specimen 1 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109Public - Test Data Visible
2021-07-28-11-3ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Anthony Valdez, CT HQ - Sacramento Cement Testing Laboratory10/11/2021
Yes
11/04/20217 day test -- Specimen 2 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109Public - Test Data Visible
2021-07-28-11-4ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)Anthony Valdez, CT HQ - Sacramento Cement Testing Laboratory11/01/2021
Yes
11/04/202128 day test -- Invalid test: variation in specimen strengths exceeds allowable limits of ASTM C109. This is a failure of the test, not of the material.Public - Test Data Visible
2021-07-28-11-5ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement MortarAnthony Valdez, CT HQ - Sacramento Cement Testing Laboratory09/23/2021
Yes
11/04/2021Public - Test Data Visible
2021-07-28-11-6ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat NeedleAnthony Valdez, CT HQ - Sacramento Cement Testing Laboratory11/03/2021
Yes
11/04/2021Public - Test Data Visible
2021-07-28-11-7ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability ApparatusAnthony Valdez, CT HQ - Sacramento Cement Testing Laboratory08/12/2021
Yes
11/04/2021Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-07-28-11-2 ASTM C109-16a (Verified)
DIME Test ID: 2021-07-28-11-3 ASTM C109-16a (Verified)
DIME Test ID: 2021-07-28-11-4 ASTM C109-16a (Verified)
DIME Test ID: 2021-07-28-11-5 ASTM C185-15a (Verified)
DIME Test ID: 2021-07-28-11-6 ASTM C191-13 (Verified)
DIME Test ID: 2021-07-28-11-7 ASTM C204-11 (Verified)