Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2021-07-21-4
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
| Award Date | 11/29/2012 |
| Closeout Date | 07/31/2023 |
| Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
| Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
| Sample Taken Date | 07/21/2021 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/26/2021 |
| Sample type | Quality Assurance | A brief description of the sample | 0.6" prestress steel strands |
| The quantity of what the sample constitutes | 2 Coils | From where was the sample collected | Other |
| First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 6466327821 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Schwager-Davis | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 134-114-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | 0647, 0651 | Number of Coils | 2 |
| Group Number | Strand Diameter | .6 in | |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | 23402 | Mfg. Lot Number(s) | 23402 |
| Manufacturer(s) | Schwager Davis Inc |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-07-21-4-1 ASTM A416-15 (Verified)
DIME Test ID: 2021-07-21-4-2 ASTM A416-15 (Verified)