Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2021-06-30-27
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214951 DEA: 120K0234 EFIS: 1214000100 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-17.1/18.9 |
| Award Date | 09/23/2020 |
| Closeout Date | Not set |
| Work Description | South County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS. |
| Location Description | ORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/01/2020) |
Sample Information
| Sample Taken Date | 06/30/2021 | Sample Unique Key | 27 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/12/2021 |
| Sample type | Quality Assurance | A brief description of the sample | 2-1/2 x 60 |
| The quantity of what the sample constitutes | 190 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Oscar | Last name of sampler or witnessed by | Vizcaino |
| Title of sampler | Telephone number of sampler | 6787558969 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Madden Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3105254 | Nut Mfg. Lot Number(s) | DEAH DECN |
| Washer Mfg. Lot Number(s) | 0121-699 | Bolt Specification | ASTM F1554 |
| Bolt Length(s) | 60" | Nut Specification | ASTM A194-2H/ A563-DH |
| Washer Specification | ASTM F436 | Finish | A153/A123 HDG |
| Diameter/Size | 2.5" | Bolt Mfg. Lot Number | 3105254 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-06-30-27-1 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-27-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-27-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-27-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-27-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-27-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-27-7 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-27-8 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-27-9 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-27-10 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-27-11 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-27-12 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-27-13 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-27-14 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-27-15 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-27-16 ASTM E18-15 (Verified)
DIME Test ID: 2021-06-30-27-17 ASTM E18-15 (Verified)
DIME Test ID: 2021-06-30-27-18 ASTM E18-15 (Verified)
DIME Test ID: 2021-06-30-27-19 ASTM E18-15 (Verified)
DIME Test ID: 2021-06-30-27-20 ASTM A370-15 (Verified)
DIME Test ID: 2021-06-30-27-21 ASTM A370-15 (Verified)