Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2021-07-08-2
Project Information
| Project Identifiers | Project ID: 214993 DEA: 051F5004 EFIS: 0514000003 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101,135-70.6/71.2;0.1 |
| Award Date | 11/17/2020 |
| Closeout Date | 01/11/2024 |
| Work Description | CONSTRUCT CONCRETE BRIDGE, BRIDGE REMOVAL, COLD PLANE, PLACE HMA. |
| Location Description | SANTA BARBARA COUNTY AT LOS ALAMOS ON ROUTE 101 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 101/135 SEPARATION AND ON ROUTE 135 AT ROUTE 101/135 SEPARATION |
| QA Service Level | 1 (Verified on 09/03/2020) |
Sample Information
| Sample Taken Date | 07/08/2021 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
| Sample type | Quality Control | A brief description of the sample | #11 headed rebar |
| The quantity of what the sample constitutes | 28 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 6466327821 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Headed Reinforcement Corp, Fountain Valley, CA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-109-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 3500015879 | Head Manufacturer Lot Number(s) | 1 |
| Rebar Size | #11 | Headed Bar Model Name | HRC 120 T Heads |
| Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
| Head Shape | Square | Rebar Manufacturer | Nucor Seattle |
| Head Manufacturer | Headed Reinforcement Corp | Head Fabricator | Headed Reinforcement Corp |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| No results found. | |||||||||
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||