Sample Record
DIME Sample ID 2021-04-09-22
Project Information
| Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Owner Lab
- CT HQ - Sacramento Cement Testing Laboratory
Sample Information
| Sample Taken Date | 04/09/2021 | Sample Unique Key | 22 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/09/2021 | Sample type | Annual Source Testing |
| A brief description of the sample | Fly Ash | The quantity of what the sample constitutes | 1 Bucket |
| From where was the sample collected | Source | First name of sampler or witnessed by | N/A |
| Last name of sampler or witnessed by | NA | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | CM215190 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Golden State Pozzolan | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | Golden State Pozzolan |
|---|---|---|---|
| Mill | GSP Class N Pozzolan | Type of Cementitious Material | Class F or N Flyash |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2021-04-09-22-2 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Anthony Valdez, CT HQ - Sacramento Cement Testing Laboratory | 05/18/2021 | No | |||||
| 2021-04-09-22-3 | ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) | Anthony Valdez, CT HQ - Sacramento Cement Testing Laboratory | 06/08/2021 | No | |||||
| 2021-04-09-22-4 | ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve | Anthony Valdez, CT HQ - Sacramento Cement Testing Laboratory | 04/22/2021 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-04-09-22-2 ASTM C109-16a
DIME Test ID: 2021-04-09-22-3 ASTM C109-16a
DIME Test ID: 2021-04-09-22-4 ASTM C430-8