Sample Record

Owner Lab

  • CT - Unassigned/General Field Laboratory

DIME Sample ID 2021-04-16-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date04/16/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/20/2021
Sample typeQuality Assurance A brief description of the sampleHRC 120 T-Heads
The quantity of what the sample constitutes24 From where was the sample collectedSource
First name of sampler or witnessed byLeslie Last name of sampler or witnessed byGuerrero
Title of samplerQuality Assurance Inspector Telephone number of sampler4242338040
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHeaded Reinforcement Corp, Fountain Valley, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL153-018-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4104575 Head Manufacturer Lot Number(s)Lot 1
Rebar Size#10 Headed Bar Model NameHRC 120
Size of HeadFull Size - 9x Head Connection Type
Head ShapeSquare Rebar ManufacturerCMC Steel Arizona
Head ManufacturerNucor Head FabricatorHeaded Reinforcement Corp
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-04-16-1-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/21/2021bewing
Yes
04/21/2021Ok Necking
2021-04-16-1-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/21/2021bewing
Yes
04/21/2021Ok Necking
2021-04-16-1-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/21/2021bewing
Yes
04/21/2021Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-04-16-1-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-04-16-1-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-04-16-1-3 ASTM A970-15e1 (Verified)