Sample Record
DIME Sample ID 2020-11-10-9
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214832 DEA: 031J0804 EFIS: 0320000080 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-50-L0.01 |
| Award Date | 11/13/2019 |
| Closeout Date | 06/27/2022 |
| Work Description | Repair bottom flanges of scraped girders,repair or replace lateral bracing elements and replace damaged sections of catwalk. Install vertical clearances gages on fenders as directed by USCG. |
| Location Description | In Sacramento County in Sacramento on Route 50 at teh Sacramento RIver Viaduct(Pioneer) Bridges #24 0004L/R |
| QA Service Level | 1 (Verified on 03/24/2020) |
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 11/10/2020 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/12/2020 | Sample type | Quality Assurance |
| A brief description of the sample | A325 HDG Rocap Assembiy | The quantity of what the sample constitutes | 110 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | D |
| Last name of sampler or witnessed by | Munoz | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Fontana Nucor TSI | |
| Transportation Laboratory (TL) Number | C836611 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 7454 01 8755 01 |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 390804A | |
| Washer Mfg. Lot Number(s) | 0620 492 | Bolt Specification | A3125 A325 |
| Bolt Length(s) | 2 | Nut Specification | A194 |
| Washer Specification | F436 | Finish | F2329 |
| Diameter/Size | .875 | Bolt Mfg. Lot Number | 757838 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Green | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-11-10-9-1 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-7 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-8 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-9 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-10 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-11 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-12 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-13 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-14 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-15 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-16 ASTM E18-15 (Verified)
DIME Test ID: 2020-11-10-9-17 ASTM E18-15 (Verified)
DIME Test ID: 2020-11-10-9-18 ASTM E18-15 (Verified)
DIME Test ID: 2020-11-10-9-19 ASTM E18-15 (Verified)
DIME Test ID: 2020-11-10-9-20 ASTM F606-14a (Verified)