Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2020-09-24-17
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
| Award Date | 12/03/2019 |
| Closeout Date | 09/28/2022 |
| Work Description | San Mateo US 101 Express Lanes North |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 09/24/2020 | Sample Unique Key | 17 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/27/2020 | Sample type | Quality Assurance |
| A brief description of the sample | HRC 500 510 Couplers | The quantity of what the sample constitutes | 200 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Shady |
| Last name of sampler or witnessed by | Besada | Title of sampler | ASR |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Pacific Steel Group | |
| Transportation Laboratory (TL) Number | C613892 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Nucor |
| Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | |
| Rebar Size | #8 | Coupler Model | HRC 500 / 510 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | A193741 351818 | Rebar Heat Number(s) | 3500010655 |
| Rebar Size 2 | Coupler Unique ID | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-09-24-17-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-09-24-17-2 CTM 670-December 2013 (Verified)