Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2020-10-05-5

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date10/05/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing10/09/2020
Sample typePreliminary A brief description of the sample#5 Black Steel with Coupler
The quantity of what the sample constitutes16 From where was the sample collectedJob Site
First name of sampler or witnessed byEmanuel Last name of sampler or witnessed bySantamaria
Title of samplerMaterials Control Coordinator Telephone number of sampler(909) 557-3818
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBar Splice Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameSultana

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerBar Splice Products Intermediate Assembler or FabricatorCMC Rebar
Rebar Size#5 Coupler ModelZaplock 05DBZA
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)Heat number 8163 Production Run S3814R7-5DBZ Rebar Heat Number(s)4100995
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-10-05-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/20/2020fsaylor
Yes
10/20/2020Service splice
2020-10-05-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/20/2020fsaylor
Yes
10/20/2020Service splice
2020-10-05-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/20/2020fsaylor
Yes
10/20/2020Service splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-10-05-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-10-05-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2020-10-05-5-3 CTM 670-December 2013 (Verified)