Sample Record
Owner Lab
- Kiewit Infrastructure West Company - Redwood City
DIME Sample ID 2020-08-20-37
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
| Award Date | 12/03/2019 |
| Closeout Date | 09/28/2022 |
| Work Description | San Mateo US 101 Express Lanes North |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 08/20/2020 | Sample Unique Key | 37 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/21/2020 | Sample type | Quality Control |
| A brief description of the sample | PCC Core | The quantity of what the sample constitutes | 36 CY |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Talen |
| Last name of sampler or witnessed by | Trajkovski | Title of sampler | Field Technician |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Central Concrete Supply | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | SW 6 Pier 119, 120 | |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | DDLSP8Q3 |
|---|---|---|---|
| The truck number from where the sample was collected | 6215 | The batch plant ticket number from where the sample was collected | 18087084 |
| Concrete batch plant | Central Concrete South SFO Plant | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | SW 6 San Mateo | Where the material sample would have been placed if not sampled | SW CIDH Pier |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-08-20-37-1 ASTM C39-18 (Verified)