Sample Record

DIME Sample ID 2020-06-02-34

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214589
DEA: 020J1604
DIST-CO-RTE-PM02-PLU-284-0.0/8.3
Award Date02/11/2020
Closeout Date10/06/2020
Work DescriptionPLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING).
Location DescriptionPLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072
QA Service Level1 (Verified on 01/22/2020)

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

Sample Information

Sample Taken Date06/02/2020 Sample Unique Key34
Date that the sample was received by the laboratory/organization performing the testing06/11/2020 Sample typeDepartment Acceptance
A brief description of the sample3/4" Shoulder Backing The quantity of what the sample constitutes9000 tons
From where was the sample collectedManufacturer First name of sampler or witnessed byA
Last name of sampler or witnessed bySloaterman Title of sampler
Telephone number of sampler Laboratory sample identificationD78469
Linked DIME Sample ID The fabricator/manufacturer/facility nameJoy Engineering
Transportation Laboratory (TL) Number896985 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-32-0032 SPARROCK BAR ONE QUARRY
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2020-06-02-34-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesArthur Mills, CT D02 - Redding Northern Regional Laboratory06/18/2020
Yes
09/16/2020Public - Test Data Visible
2020-06-02-34-2CTM 217-June 2011: Method of Test for Sand EquivalentArthur Mills, CT D02 - Redding Northern Regional Laboratory06/18/2020
Yes
09/16/2020Public - Test Data Visible
2020-06-02-34-3CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)Darrell Valasek, CT D02 - Redding Northern Regional Laboratory06/18/2020
Yes
09/16/2020Public - Test Data Visible
2020-06-02-34-4CTM 229-June 2011: Method of Test for Durability IndexArthur Mills, CT D02 - Redding Northern Regional Laboratory06/18/2020
Yes
09/16/2020Public - Test Data Visible
2020-06-02-34-5CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerTerry McCormick, CT D02 - Redding Northern Regional Laboratory06/18/2020
Yes
09/16/2020Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-06-02-34-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2020-06-02-34-2 CTM 217-June 2011 (Verified)
DIME Test ID: 2020-06-02-34-3 CTM 204-June 2010 (Verified)
DIME Test ID: 2020-06-02-34-4 CTM 229-June 2011 (Verified)
DIME Test ID: 2020-06-02-34-5 CTM 301-March 2000 (Verified)