Sample Record

DIME Sample ID 2020-08-21-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Owner Lab

  • CT HQ - QASI Bay Area Field Office

Sample Information

Sample Taken Date08/21/2020 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing08/21/2020 Sample typeQuality Assurance
A brief description of the sample5/8" A563-DH Plain HEX NUT The quantity of what the sample constitutes9/169
Sample sizeNot set From where was the sample collectedFabricator
First name of sampler or witnessed byDong Last name of sampler or witnessed byShin
Title of samplerQA Inspector Telephone number of sampler205-999-5798
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Lindon UT Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB 314-068-20 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)No
Heat Number(s)6215177505 Nut Mfg. Lot Number(s)32878-6215177505
Washer Mfg. Lot Number(s)N/A Bolt SpecificationN/A
Bolt Length(s)N/A Nut SpecificationA563-DH
Washer SpecificationN/A FinishPlain
Diameter/Size5/8" Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s)No Lubricant Requirements(s)No
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2020-08-21-1-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/27/202008/27/2020
Yes
09/02/2020Nut ProofPublic - Test Data Visible
2020-08-21-1-2ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/28/2020
Yes
09/02/2020Public - Test Data Visible
2020-08-21-1-3ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/28/2020
Yes
09/02/2020Public - Test Data Visible
2020-08-21-1-4ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/28/2020
Yes
09/02/2020Public - Test Data Visible
2020-08-21-1-5ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory09/15/202009/15/2020
No
Nut Proof Info

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-08-21-1-1 ASTM F606-14a (Verified)
DIME Test ID: 2020-08-21-1-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-08-21-1-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-08-21-1-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-08-21-1-5 ASTM F606-14a