Sample Record
DIME Sample ID 2020-06-02-3
Project Information
| Project Identifiers | Project ID: 213682 DEA: 11430184 EFIS: 1117000215 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-8.4/8.8 |
| Award Date | 12/13/2018 |
| Closeout Date | 09/14/2023 |
| Work Description | Bridge widening, HMA, barrier, drainage, RCP, and landscape work near Sweetwater River Bridge in Chula Vista. Widening of Sweetwater River Bridge in Chula Vista on 805. |
| Location Description | Near Sweetwater River Bridge in Chula Vista on 805. |
| QA Service Level | 1 (Verified on 06/01/2020) |
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 06/02/2020 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/04/2020 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM A706 GR 60 Headed Bar | The quantity of what the sample constitutes | 8 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Arthur |
| Last name of sampler or witnessed by | Peterson | Title of sampler | QA Inspector |
| Telephone number of sampler | 707-342-8602 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Pacific Steel Group | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-119-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 1202016630 | Head Manufacturer Lot Number(s) | Lot no 1 and Lot no 2 |
| Rebar Size | #8 | Headed Bar Model Name | HRC 555 |
| Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
| Head Shape | Circular | Rebar Manufacturer | Nucor |
| Head Manufacturer | Nucor | Head Fabricator | Pacific Steel Group |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-06-02-3-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-06-02-3-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-06-02-3-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-06-02-3-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-06-02-3-5 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-06-02-3-6 ASTM A970-15e1 (Verified)