Sample Record

DIME Sample ID 2019-08-27-1

Project Information

Project IdentifiersProject ID: 213682
DEA: 11430184
EFIS: 1117000215
DIST-CO-RTE-PM11-SD-805-8.4/8.8
Award Date12/13/2018
Closeout Date09/14/2023
Work DescriptionBridge widening, HMA, barrier, drainage, RCP, and landscape work near Sweetwater River Bridge in Chula Vista. Widening of Sweetwater River Bridge in Chula Vista on 805.
Location DescriptionNear Sweetwater River Bridge in Chula Vista on 805.
QA Service Level1 (Verified on 06/01/2020)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date08/27/2019 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing08/30/2019 Sample typeQuality Assurance
A brief description of the sample#5 Ultimate Splice Welded Hoops The quantity of what the sample constitutes12
From where was the sample collectedFabricator First name of sampler or witnessed byArthur
Last name of sampler or witnessed byPeterson Title of samplerQA Inspector
Telephone number of sampler707-342-8602 Laboratory sample identificationLot 1 Lot 6 and Lot 10
Linked DIME Sample ID The fabricator/manufacturer/facility nameTNT Rebar Company
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL110-113-19
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL17107881
Hoop Manufacturer Lot Number(s)PL1710788151 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop2'-0.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor Utah
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-08-27-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/201909/05/2019
Yes
09/05/2019OK NeckingPublic - Test Data Visible
2019-08-27-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/201909/05/2019
Yes
09/05/2019OK NeckingPublic - Test Data Visible
2019-08-27-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/201909/05/2019
Yes
09/05/2019OK NeckingPublic - Test Data Visible
2019-08-27-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/201909/05/2019
Yes
09/05/2019OK NeckingPublic - Test Data Visible
2019-08-27-1-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/201909/05/2019
Yes
09/05/2019OK NeckingPublic - Test Data Visible
2019-08-27-1-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/201909/05/2019
Yes
09/05/2019OK NeckingPublic - Test Data Visible
2019-08-27-1-7CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/201909/05/2019
Yes
09/05/2019OK NeckingPublic - Test Data Visible
2019-08-27-1-8CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/201909/05/2019
Yes
09/05/2019OK NeckingPublic - Test Data Visible
2019-08-27-1-9CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/05/201909/05/2019
Yes
09/05/2019OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-08-27-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-27-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-27-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-27-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-27-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-27-1-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-27-1-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-27-1-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-27-1-9 CTM 670-December 2013 (Verified)