Sample Record

DIME Sample ID 2019-08-20-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214283
DEA: 044Q0304
EFIS: 0419000306
DIST-CO-RTE-PM04-SON-1-11.2, 11.20
Award Date05/01/2019
Closeout Date06/20/2022
Work DescriptionREPLACE FAILED 60" CMP CULVERT WITH 10'x10' PRECAST REINFORCED CONCRETE BOX
Location DescriptionNot set
QA Service Level1 (Verified on 08/19/2019)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/20/2019 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing08/22/2019 Sample typeQuality Assurance
A brief description of the sample Couplers The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byDavid
Last name of sampler or witnessed byNA Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Dayton Superior
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size6 Coupler ModelBar Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A180949 Rebar Heat Number(s)9001331
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-08-20-8-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/28/201908/28/2019
Yes
09/04/2019Public - Test Data Visible
2019-08-20-8-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/28/201908/28/2019
Yes
09/04/2019Service SplicePublic - Test Data Visible
2019-08-20-8-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory08/28/201908/28/2019
Yes
09/04/2019Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-08-20-8-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-20-8-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-20-8-3 CTM 670-December 2013 (Verified)