Sample Record

DIME Sample ID 2019-06-21-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213747
DEA: 080Q9104
EFIS: 0800020580
DIST-CO-RTE-PM08-SBD-10-R23.8
Award Date01/30/2019
Closeout Date07/27/2022
Work DescriptionRETROFIT BRIDGE PIER WALLS, FOOTINGS AND POLYESTER CONCRETE OVERLAY.
Location DescriptionSAN BERNARDINO COUNTY IN COLTON AT THE SANTA ANA RIVER BRIDGES
QA Service Level1 (Verified on 03/18/2019)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date06/21/2019 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing06/24/2019 Sample typeQuality Assurance
A brief description of the sampleATB A722 plus couplers and hardware The quantity of what the sample constitutes6 bars, 1 coupler, 6 hex nuts
From where was the sample collectedFabricator First name of sampler or witnessed byCarolina
Last name of sampler or witnessed byBurgan Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameWilliams Form Engineering
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar Type Rebar Size
Nut Specification for Threaded BarUnknown System ManufacturerUnknown
Epoxy Coating ColorNA Threaded Bar Application
Coating StandardsUncoated Bar Heat Number(s)1000796073, 1000891061, 100891062
Nut Heat Number(s)75072337 (64D1D) Bar Lot NumberUnknown
Nut Lot NumberUnknown Coupler Heat Number(s)C158181 (64U8D)
Coupler GradeUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2019-06-21-1-1ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/201907/03/2019
Yes
07/03/2019#1 Bar Heat #100891061Public - Test Data Visible
2019-06-21-1-2ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/201907/03/2019
Yes
07/03/2019#1 Bar Heat# 100891062Public - Test Data Visible
2019-06-21-1-3ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/201907/03/2019
Yes
07/03/2019Bar 3 Heat # 100891062 with Coupler Bar Broke in GripPublic - Test Data Visible
2019-06-21-1-4ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/201907/03/2019
Yes
07/03/2019#1 Bar Heat #100796073Public - Test Data Visible
2019-06-21-1-5ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/201907/03/2019
Yes
07/03/2019Bar 2 Heat#100796073 ElongationPublic - Test Data Visible
2019-06-21-1-6ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/201907/03/2019
Yes
07/03/2019Bar 2 Heat#100891061 ElongationPublic - Test Data Visible
2019-06-21-1-7ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/02/201907/03/2019
Yes
07/03/2019Bar # 2 Heat# 100891062 ElongationPublic - Test Data Visible
2019-06-21-1-8ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/03/201907/03/2019
Yes
07/03/2019Bar 3 Heat # 100891062 with Coupler Test OnlyPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-06-21-1-1 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-2 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-3 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-4 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-5 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-6 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-7 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-8 ASTM A722-15 (Verified)