Sample Record
DIME Sample ID 2019-06-21-1
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 213747 DEA: 080Q9104 EFIS: 0800020580 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-10-R23.8 |
| Award Date | 01/30/2019 |
| Closeout Date | 07/27/2022 |
| Work Description | RETROFIT BRIDGE PIER WALLS, FOOTINGS AND POLYESTER CONCRETE OVERLAY. |
| Location Description | SAN BERNARDINO COUNTY IN COLTON AT THE SANTA ANA RIVER BRIDGES |
| QA Service Level | 1 (Verified on 03/18/2019) |
Owner Lab
- CT HQ - QASI Los Angeles Field Office
Sample Information
| Sample Taken Date | 06/21/2019 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/24/2019 | Sample type | Quality Assurance |
| A brief description of the sample | ATB A722 plus couplers and hardware | The quantity of what the sample constitutes | 6 bars, 1 coupler, 6 hex nuts |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Carolina |
| Last name of sampler or witnessed by | Burgan | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Williams Form Engineering | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
| Threaded Bar Type | Rebar Size | ||
| Nut Specification for Threaded Bar | Unknown | System Manufacturer | Unknown |
| Epoxy Coating Color | NA | Threaded Bar Application | |
| Coating Standards | Uncoated | Bar Heat Number(s) | 1000796073, 1000891061, 100891062 |
| Nut Heat Number(s) | 75072337 (64D1D) | Bar Lot Number | Unknown |
| Nut Lot Number | Unknown | Coupler Heat Number(s) | C158181 (64U8D) |
| Coupler Grade | Unknown |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-06-21-1-1 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-2 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-3 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-4 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-5 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-6 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-7 ASTM A722-15 (Verified)
DIME Test ID: 2019-06-21-1-8 ASTM A722-15 (Verified)