Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2019-05-02-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 213617 DEA: 100P5504 EFIS: 1012000055 |
|---|---|
| DIST-CO-RTE-PM | 10-AMA,STA-88,152-4.6 |
| Award Date | 11/09/2018 |
| Closeout Date | 08/03/2021 |
| Work Description | Aqueduct bridge seismic retrofit. CURED IN PLACE PIPE LINER AT 0.6 MILES WEST OF MARIN LANE NEAR IONE IN AMADOR COUNTY. |
| Location Description | MERCED AND STANISLAUS COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 12/20/2018) |
Sample Information
| Sample Taken Date | 05/02/2019 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/08/2019 |
| Sample type | Quality Assurance | A brief description of the sample | 1-1/4" F1554 Gr. 55 Galv. ATR 1 Lot |
| The quantity of what the sample constitutes | 1 lot | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Adame |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 3609531155 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CK Johnson Industries | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B53-038-19 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
|---|---|---|---|
| Heat Number(s) | 1201000624 | Nut Mfg. Lot Number(s) | 369544B |
| Washer Mfg. Lot Number(s) | 0918-971 | Bolt Specification | F1554 |
| Bolt Length(s) | 16" | Nut Specification | A563 HVY HX HDG |
| Washer Specification | F436 HDG | Finish | HDG |
| Diameter/Size | 1-1/4" | Bolt Mfg. Lot Number | B1124809 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-05-02-2-1 ASTM A370-15 (Verified)
DIME Test ID: 2019-05-02-2-2 ASTM A370-15 (Verified)
DIME Test ID: 2019-05-02-2-3 ASTM F606-14a (Verified)
DIME Test ID: 2019-05-02-2-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-05-02-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-05-02-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-05-02-2-7 ASTM B499-14 (Verified)
DIME Test ID: 2019-05-02-2-8 ASTM B499-14 (Verified)
DIME Test ID: 2019-05-02-2-9 ASTM B499-14 (Verified)
DIME Test ID: 2019-05-02-2-10 ASTM B499-14 (Verified)
DIME Test ID: 2019-05-02-2-11 ASTM B499-14 (Verified)
DIME Test ID: 2019-05-02-2-12 ASTM B499-14 (Verified)
DIME Test ID: 2019-05-02-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2019-05-02-2-14 ASTM B499-14 (Verified)
DIME Test ID: 2019-05-02-2-15 ASTM B499-14 (Verified)
DIME Test ID: 2019-05-02-2-16 ASTM E18-15 (Verified)
DIME Test ID: 2019-05-02-2-17 ASTM E18-15 (Verified)