Sample Record
DIME Sample ID 2019-04-09-7
Sample is locked from editing. info
Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 04/09/2019 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/15/2019 | Sample type | Quality Assurance |
| A brief description of the sample | Coupon Casting | The quantity of what the sample constitutes | 6 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Michelle |
| Last name of sampler or witnessed by | Haughey | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | SDI Farrar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | B229 B279 C069 C159 C209 C219 |
|---|---|---|---|
| Part Number (s) | SDi 22 6 AH 22 6 BP 19 6 BP 22 6 AH 22 6 | Material Specification | A536 |
| Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar Corporation |
| Prestressing Manufacturer | SDI |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-04-09-7-1 ASTM A370-15 (Verified)