Sample Record

DIME Sample ID 2018-11-05-4

Project Information

Project IdentifiersProject ID: 211931
DEA: 043G6414
EFIS: 0416000348
DIST-CO-RTE-PM04-NAP-29-37.0
Award Date03/17/2017
Closeout Date04/22/2020
Work DescriptionSCOUR REPLACE BRIDGE
Location DescriptionNAPA COUNTY IN CALISTOGA AT NAPA RIVER BRIDGE
QA Service Level1 (Verified on 02/15/2017)

Owner Labs

  • CT SC - 3676 - 106
  • CT HQ - Sacramento Concrete Testing Laboratory

Sample Information

Sample Taken Date11/05/2018 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing11/08/2018 Sample typeDepartment Acceptance
A brief description of the sample6 X 12 Concrete Cylinder The quantity of what the sample constitutes90.0 CY
From where was the sample collectedJob Site First name of sampler or witnessed byNana
Last name of sampler or witnessed byBudu Title of samplerAssistant Structure Representative
Telephone number of sampler510-867-4517 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHarold Smith
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierBridge Deck Stage 3 Structure nameNapa River Bridge Calistoga
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCT1 P15
The truck number from where the sample was collectedTruck No 125 The batch plant ticket number from where the sample was collected151245
Concrete batch plantHarold Smith St Helena The fabricator/manufacturer designation for the sampleHarold Smith
A detailed description of where the material sample was collectedBack of Pump Truck Where the material sample would have been placed if not sampledBridge Deck
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-11-05-4-1ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensRM, CT HQ - Sacramento Concrete Testing Laboratory12/03/201812/03/2018
Yes
12/03/2018Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-11-05-4-1 ASTM C39-10 (Verified)