Sample Record

DIME Sample ID 2018-11-01-2

Sample is locked from editing. info

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date11/01/2018 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing11/09/2018 Sample typeQuality Assurance
A brief description of the sampleF1554 Grade 55 HDG Anchor Bolts The quantity of what the sample constitutes3
From where was the sample collectedFabricator First name of sampler or witnessed byKevin
Last name of sampler or witnessed byChurchill Title of samplerQA Inspector
Telephone number of sampler510-693-3545 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameA and M Nut and Bolt
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL02-083-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)58034809-08 Nut Mfg. Lot Number(s)27674-17791
Washer Mfg. Lot Number(s)304172 Bolt SpecificationF1554 Gr55
Bolt Length(s)18" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot Number44080-PP0
Rocap Test Requirement(s) Lubricant Requirements(s)Yes
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-11-01-2-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/201811/08/2018
Yes
11/21/2018Nut Proof LoadPublic - Test Data Visible
2018-11-01-2-2ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/201811/08/2018
Yes
11/21/2018Public - Test Data Visible
2018-11-01-2-3ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/201811/08/2018
Yes
11/21/2018Nut Proof LoadPublic - Test Data Visible
2018-11-01-2-4ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/201811/08/2018
Yes
11/21/2018Public - Test Data Visible
2018-11-01-2-5ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/2018
Yes
11/21/2018Public - Test Data Visible
2018-11-01-2-6ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/2018
Yes
11/21/2018Public - Test Data Visible
2018-11-01-2-7ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/2018
Yes
11/21/2018Public - Test Data Visible
2018-11-01-2-8ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/2018
Yes
11/21/2018Public - Test Data Visible
2018-11-01-2-9ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/2018
Yes
11/21/2018Public - Test Data Visible
2018-11-01-2-10ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/08/2018
Yes
11/21/2018Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-11-01-2-1 ASTM F606-14a (Verified)
DIME Test ID: 2018-11-01-2-2 ASTM A370-15 (Verified)
DIME Test ID: 2018-11-01-2-3 ASTM F606-14a (Verified)
DIME Test ID: 2018-11-01-2-4 ASTM A370-15 (Verified)
DIME Test ID: 2018-11-01-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-11-01-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-11-01-2-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-11-01-2-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-11-01-2-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-11-01-2-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-11-01-2-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-11-01-2-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-11-01-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-14 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-15 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-16 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-17 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-18 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-19 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-20 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-21 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-22 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-23 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-24 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-25 ASTM B499-14 (Verified)
DIME Test ID: 2018-11-01-2-26 ASTM E18-15 (Verified)
DIME Test ID: 2018-11-01-2-27 ASTM E18-15 (Verified)
DIME Test ID: 2018-11-01-2-28 ASTM E18-15 (Verified)