Sample Record
DIME Sample ID 2026-06-09-68
Project Information
| Project Identifiers | Project ID: 994654 DEA: 07313504 EFIS: 0715000090 |
|---|---|
| DIST-CO-RTE-PM | 07-LA,VEN-1-37.7/62.9,0.0/0.9 |
| Award Date | 07/20/2023 |
| Closeout Date | Not set |
| Work Description | REMOVE AND CONSTRUCT BRIDGE AND CULVERTS. |
| Location Description | LOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS FROM 0.4 MILE SOUTH OF TEMESCAL CANYON ROAD TO 0.1 MILE NORTH OF TONGA STREET |
| QA Service Level | 1 (Verified on 07/24/2023) |
Owner Lab
- G3 Quality, Incorporated - Cerritos
Sample Information
| Sample Taken Date | 06/09/2026 | Sample Unique Key | 68 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/09/2026 | Sample type | Quality Control |
| A brief description of the sample | 4x8 cylinders | The quantity of what the sample constitutes | 5 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Grayson |
| Last name of sampler or witnessed by | Krupp | Title of sampler | QC Field Technician |
| Telephone number of sampler | Laboratory sample identification | SL675350CE | |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Associated Ready Mix |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | 00-0000 | Structure name | Abut 1 CIDH 7 & 10, Abut 2 CIDH 7 |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SL675350CE |
|---|---|---|---|
| The truck number from where the sample was collected | Load 2 | The batch plant ticket number from where the sample was collected | 0 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | Set 1 | |
| A detailed description of where the material sample was collected | Abut 1 CIDH 7 & 10, Abut 2 CIDH 7 | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2026-06-09-68-1 | CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete | Grayson Krupp, G3 Quality, Incorporated - Cerritos | 06/09/2026 | 10/27/2026 | No | ||||
| 2026-06-09-68-2 | CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete | Grayson Krupp, G3 Quality, Incorporated - Cerritos | 06/09/2026 | 10/27/2026 | No | ||||
| 2026-06-09-68-3 | CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method | Grayson Krupp, G3 Quality, Incorporated - Cerritos | 06/09/2026 | 10/27/2026 | No | ||||
| 2026-06-09-68-4 | CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete | Grayson Krupp, G3 Quality, Incorporated - Cerritos | 06/09/2026 | 10/27/2026 | No | ||||
| 2026-06-09-68-5 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | Jose Garibaldo, G3 Quality, Incorporated - Cerritos | 07/02/2026 | 10/27/2026 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2026-06-09-68-1 CTM 557-June 2020
DIME Test ID: 2026-06-09-68-2 CTM 518-June 2010
DIME Test ID: 2026-06-09-68-3 CTM 504-June 2010
DIME Test ID: 2026-06-09-68-4 CTM 556-January 2018
DIME Test ID: 2026-06-09-68-5 CTM 521-June 2020