Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2026-07-29-29

Project Information

Project IdentifiersProject ID: 993118
DEA: 101C3304
EFIS: 1014000146
DIST-CO-RTE-PM10-SJ-205-R4.6/R9.0
Award Date04/05/2022
Closeout DateNot set
Work DescriptionWidening bridges, ramps and roadway. SR205 SMART CORRIDOR - PHASE 2
Location DescriptionOn state highway in San Joaquin County in and near Tracy from Janney Overhead to 1.3 miles east of MacArthur Drive Overcrossing.
QA Service Level1 (Verified on 07/06/2022)

Sample Information

Sample Taken Date07/29/2026 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/31/2026
Sample typeQuality Assurance A brief description of the sample#11 Coupler
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byJohnsky Last name of sampler or witnessed byOveny
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameC&N Reinforcment Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73142156, 73142654 Rebar Heat Number(s)9012799, 9012800
Rebar Size 2 Coupler Unique IDTP-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-07-29-29-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/202608/10/2026
Yes
08/10/2026 

Sample File Attachments

File NameExtensionDate UploadedActions
M0803-1790 Dime Number 2026-07-29-29pdf08/10/2026   Info

Test File Attachments


DIME Test ID: 2026-07-29-29-1 CTM 670-December 2013 (Verified)