Sample Record
Owner Lab
- G3 Quality, Incorporated - Cerritos
DIME Sample ID 2026-03-19-69
Project Information
| Project Identifiers | Project ID: 994654 DEA: 07313504 EFIS: 0715000090 |
|---|---|
| DIST-CO-RTE-PM | 07-LA,VEN-1-37.7/62.9,0.0/0.9 |
| Award Date | 07/20/2023 |
| Closeout Date | Not set |
| Work Description | REMOVE AND CONSTRUCT BRIDGE AND CULVERTS. |
| Location Description | LOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS FROM 0.4 MILE SOUTH OF TEMESCAL CANYON ROAD TO 0.1 MILE NORTH OF TONGA STREET |
| QA Service Level | 1 (Verified on 07/24/2023) |
Sample Information
| Sample Taken Date | 03/19/2026 | Sample Unique Key | 69 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/20/2026 |
| Sample type | Quality Control | A brief description of the sample | 4x8 cylinders |
| The quantity of what the sample constitutes | 5 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | James | Last name of sampler or witnessed by | Watson |
| Title of sampler | QC Field Technician | Telephone number of sampler | |
| Laboratory sample identification | SL675350CE | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Associated Ready Mix | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | 00-0000 |
| Structure name | Pile Caps | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SL675350CE |
|---|---|---|---|
| The truck number from where the sample was collected | Load 1 | The batch plant ticket number from where the sample was collected | 0 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Set 1 |
| A detailed description of where the material sample was collected | Pile Caps | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2026-03-19-69-1 | CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete | James Watson, G3 Quality, Incorporated - Cerritos | 03/19/2026 | 04/23/2026 | No | ||||
| 2026-03-19-69-2 | CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete | James Watson, G3 Quality, Incorporated - Cerritos | 03/19/2026 | 04/23/2026 | No | ||||
| 2026-03-19-69-3 | CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method | James Watson, G3 Quality, Incorporated - Cerritos | 03/19/2026 | 04/23/2026 | No | ||||
| 2026-03-19-69-4 | CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete | James Watson, G3 Quality, Incorporated - Cerritos | 03/19/2026 | 04/23/2026 | No | ||||
| 2026-03-19-69-5 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | Isac Vasquez, G3 Quality, Incorporated - Cerritos | 04/16/2026 | 04/23/2026 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2026-03-19-69-1 CTM 557-June 2020
DIME Test ID: 2026-03-19-69-2 CTM 518-June 2010
DIME Test ID: 2026-03-19-69-3 CTM 504-June 2010
DIME Test ID: 2026-03-19-69-4 CTM 556-January 2018
DIME Test ID: 2026-03-19-69-5 CTM 521-June 2020