Sample Record
DIME Sample ID 2017-10-16-1
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 209146 DEA: 06471504 EFIS: 0600000464 COOP: 061549 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-99-39.6/41.3 |
| Award Date | 02/24/2017 |
| Closeout Date | 03/03/2020 |
| Work Description | RECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT. |
| Location Description | TULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD |
| QA Service Level | 1 (Verified on 10/08/2013) |
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 10/16/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/23/2017 | Sample type | Quality Assurance |
| A brief description of the sample | 1 X 12 Anchor Rod | The quantity of what the sample constitutes | 3 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Ryan |
| Last name of sampler or witnessed by | Cummings | Title of sampler | QA Inspector |
| Telephone number of sampler | 916-718-7759 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | CK Johnson Industries |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | S-29-228-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 26307 | |
| Washer Mfg. Lot Number(s) | 0517-523 | Bolt Specification | F1554 Gr. 150 |
| Bolt Length(s) | 12 | Nut Specification | A563 DH |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1 | Bolt Mfg. Lot Number | 75065295 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2017-10-16-1-1 ASTM F606-14a (Verified)
DIME Test ID: 2017-10-16-1-2 ASTM A370-15 (Verified)
DIME Test ID: 2017-10-16-1-3 ASTM A370-15 (Verified)
DIME Test ID: 2017-10-16-1-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-10-16-1-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-10-16-1-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-10-16-1-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-10-16-1-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-10-16-1-13 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-10-16-1-14 ASTM B499-14 (Verified)
DIME Test ID: 2017-10-16-1-15 ASTM B499-14 (Verified)
DIME Test ID: 2017-10-16-1-16 ASTM B499-14 (Verified)
DIME Test ID: 2017-10-16-1-17 ASTM B499-14 (Verified)
DIME Test ID: 2017-10-16-1-18 ASTM B499-14 (Verified)
DIME Test ID: 2017-10-16-1-19 ASTM B499-14 (Verified)
DIME Test ID: 2017-10-16-1-20 ASTM B499-14 (Verified)
DIME Test ID: 2017-10-16-1-21 ASTM B499-14 (Verified)
DIME Test ID: 2017-10-16-1-22 ASTM B499-14 (Verified)
DIME Test ID: 2017-10-16-1-23 ASTM E18-15 (Verified)
DIME Test ID: 2017-10-16-1-24 ASTM E18-15 (Verified)