Sample Record

Owner Lab

  • BSK Associates

DIME Sample ID 2025-02-27-54

Project Information

Project IdentifiersProject ID: 209109
DEA: 043G9004
EFIS: 0412000557
COOP: 042513
DIST-CO-RTE-PM04-SON-116,121-46.0/46.7,5.8/R7.4
Award Date07/31/2023
Closeout DateNot set
Work DescriptionMODIFY EXISTING STATE ROUTE 116,121 BONNEAU ROAD INTERSECTION FROM A 4 WAY STOP CONTROLLED INTERSECTION TO A ROUNDABOUT AND SIGNALIZED INTERSECTION.
Location DescriptionSONOMA COUNTY
QA Service Level1 (Verified on 08/15/2022)

Sample Information

Sample Taken Date02/27/2025 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/12/2025
Sample typeProduction Start-Up A brief description of the sample3/4" HMA-RAP25%
The quantity of what the sample constitutes3 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byCody Last name of sampler or witnessed byCordero
Title of sampler Telephone number of sampler
Laboratory sample identificationD04-SE-25-003 Linked DIME Sample ID2025-02-27-55
The fabricator/manufacturer/facility nameVulcan Lake Herman Drum Plant Transportation Laboratory (TL) NumberC100561
Inspector Lot Number from the Transportation Laboratory (TL) Form1-1 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-48-0002
The fabricator's/manufacturer's product name for the sample220304 The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyer Belt-HMA Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number1 Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-02-27-54-1AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Nicholas Shelly, BSK Associates03/18/202509/05/2025
No
Coarse, 2 faced=97.9%, Coarse, 1 faced=100%; Fine, 1 faced=100%
2025-02-27-54-2AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Nicholas Shelly, BSK Associates03/18/202509/05/2025
No
Grading B, 100 revolutions=4.4%, 500 revolutions=17.9%
2025-02-27-54-3AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Nicholas Shelly, BSK Associates03/18/202509/05/2025
No
Average uncompacted voids=46.8%
2025-02-27-54-4ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Nicholas Shelly, BSK Associates03/18/202509/05/2025
No
Flat and elongated particles=0%

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-02-27-54-1 AASHTO T335-09r13
DIME Test ID: 2025-02-27-54-2 AASHTO T96-02r10
DIME Test ID: 2025-02-27-54-3 AASHTO T304-11