Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2025-07-29-63

Project Information

Project IdentifiersProject ID: 994588
DEA: 081H3904
EFIS: 0817000032
DIST-CO-RTE-PM08-SBD-15-R20.5/R21.6,R25.5/R30.7
Award Date07/13/2023
Closeout DateNot set
Work DescriptionCONSTRUCT BUILDING, ROADWAY EXC, JPCP, AND TEMPORARY BARRIER SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF CLEGHORN ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF ROUTE 138 AND FROM 0.5 MILE SOUTH OF TRUCK SAFETY CHECK AREA TO 0.4 MILE NORTH OF OAK HILL ROAD OVERCROSSING
QA Service Level1 (Verified on 08/02/2023)

Sample Information

Sample Taken Date07/29/2025 Sample Unique Key63
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/29/2025
Sample typeQuality Assurance A brief description of the sampleConcrete Cylinders
The quantity of what the sample constitutes3 From where was the sample collectedJob Site
First name of sampler or witnessed byTayo Last name of sampler or witnessed byOgeyemi
Title of samplerStructure Representative Telephone number of sampler
Laboratory sample identification1059- C3 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHi Grade Transportation Laboratory (TL) Number1059-C3
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberNOT PROVIDED
The truck number from where the sample was collected291 The batch plant ticket number from where the sample was collected2009383
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedThermal poles at A station 696+06, Speed sign pole at A Station 698+50, Light pole at A 689+00 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-07-29-63-1ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory08/05/202508/05/2025
Yes
08/05/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-07-29-63-1 ASTM C39-10 (Verified)