Sample Record

Owner Lab

  • RMA Group - Rancho Cucamonga

DIME Sample ID 2025-01-10-74

Project Information

Project IdentifiersProject ID: 994396
DEA: 07330304
EFIS: 0716000213
DIST-CO-RTE-PM07-LA-10-22.0/30.8
Award Date10/09/2023
Closeout Date09/25/2025
Work DescriptionCONSTRUCT CONCRETE BARRIER AND STRUCTURAL CONCRETE BARRIER SLAB.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.6 MILE EAST OF ROUTE 710/10 SEPARATION TO 0.3 MILE WEST OF ROUTE 10/605 SEPARATION
QA Service Level1 (Verified on 07/24/2023)

Sample Information

Sample Taken Date01/10/2025 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/10/2025
Sample typeQuality Control A brief description of the sampleSC
The quantity of what the sample constitutes6 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byLuis Last name of sampler or witnessed byPerez
Title of samplerQC Technician Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCEMEX Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameBarrier Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1610974
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNI
Concrete batch plantCEMEX The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedLocation 13, Barrier Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-01-10-74-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersJesse Lara, RMA Group - Rancho Cucamonga01/13/202508/01/2025
Yes
08/01/2025Avg. Compressive Strength = 3620psiPublic - Test Data Visible
2025-01-10-74-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersJesse Lara, RMA Group - Rancho Cucamonga01/17/202508/01/2025
Yes
08/01/2025Average Compressive Strength - 5430psiPublic - Test Data Visible
2025-01-10-74-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersJesse Lara, RMA Group - Rancho Cucamonga02/07/202508/01/2025
Yes
08/01/2025Average Compressive Strength = 6930psiPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-01-10-74-1 CTM 521-June 2020 (Verified)
File NameExtensionDate UploadedTest IDActions
22-1987 Concrete 2025-01-10 SC 1610974pdf08/01/20252025-01-10-74-1   Info

DIME Test ID: 2025-01-10-74-2 CTM 521-June 2020 (Verified)
File NameExtensionDate UploadedTest IDActions
22-1987 Concrete 2025-01-10 SC 1610974pdf08/01/20252025-01-10-74-2   Info

DIME Test ID: 2025-01-10-74-3 CTM 521-June 2020 (Verified)
File NameExtensionDate UploadedTest IDActions
22-1987 Concrete 2025-01-10 SC 1610974pdf08/01/20252025-01-10-74-3   Info