Sample Record

DIME Sample ID 2017-08-15-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211162
DEA: 044G4504
EFIS: 0412000477
DIST-CO-RTE-PM04-SOL-780-7.07
Award Date02/01/2017
Closeout Date11/15/2019
Work DescriptionREPLACE BRIDGE TO PROVIDE STANDARD VERTICAL CLEARANCE
Location DescriptionLAUREL STREET OC
QA Service Level1 (Verified on 05/20/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/15/2017 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing08/17/2017 Sample typeQuality Assurance
A brief description of the sample7 Flash Welded Hoops The quantity of what the sample constitutes8
From where was the sample collectedFabricator First name of sampler or witnessed byEd
Last name of sampler or witnessed byFleming Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC Rebar
Transportation Laboratory (TL) NumberC741501 Inspector Lot Number from the Transportation Laboratory (TL) FormB1026517
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4067059
Hoop Manufacturer Lot Number(s)1 1 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop55" 58" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Tracy) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-08-15-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201708/17/2017
Yes
08/24/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-08-15-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201708/17/2017
Yes
08/24/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-08-15-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201708/17/2017
Yes
08/24/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-08-15-7-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201708/17/2017
Yes
08/24/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-08-15-7-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201708/17/2017
Yes
08/24/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-08-15-7-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory08/17/201708/17/2017
Yes
08/24/2017Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-08-15-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-08-15-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-08-15-7-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-08-15-7-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-08-15-7-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-08-15-7-6 CTM 670-December 2013 (Verified)