Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2025-03-24-35
Project Information
| Project Identifiers | Project ID: 1000216 DEA: 081G6304 EFIS: 0816000043 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-111-47.2/55.3 |
| Award Date | 09/05/2024 |
| Closeout Date | Not set |
| Work Description | RHMA-G, REPLACE AC SURFACING, AND COLD PLANE AC PVMT. |
| Location Description | RIVERSIDE COUNTY IN PALM SPRINGS FROM GOLF CLUB DRIVE TO WEST GATEWAY DRIVE |
| QA Service Level | 1 (Verified on 05/15/2024) |
Sample Information
| Sample Taken Date | 03/24/2025 | Sample Unique Key | 35 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/25/2025 |
| Sample type | Verification | A brief description of the sample | 30k Milestone 3/4" RHMA-G-SP 0.50% LAS |
| The quantity of what the sample constitutes | 2 bags of comb agg., 1 bag of crumb rubber scrap, 1 bag of hi-natural | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Luke | Last name of sampler or witnessed by | Hall |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0177G-25 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Ingevity, CRM, SJR, Granite, VLO, West Coast Aggregate | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0072 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Belt cut at Granite Construction-Desert Hot spring | |
| Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | 1556 | Lot number | |
| Sublot number | Aggregate Mix Number |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2025-03-24-35-1 | AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis) | David Padilla/E.J., CT D08 - Fontana Southern Regional Laboratory | 03/29/2025 | 09/08/2025 | No | Combined Virgin Aggregate Gradation | |||
| 2025-03-24-35-4 | AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity) | Friday Ofoegbu, CT D08 - Fontana Southern Regional Laboratory | 03/29/2025 | 09/08/2025 | No | ||||
| 2025-03-24-35-5 | AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity) | Robert Guillen, CT D08 - Fontana Southern Regional Laboratory | 04/02/2025 | 09/08/2025 | No | ||||
| 2025-03-24-35-6 | AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler) | David Padilla, CT D08 - Fontana Southern Regional Laboratory | 04/01/2025 | 09/08/2025 | No | ||||
| 2025-03-24-35-7 | AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent) | Robert Guillen, CT D08 - Fontana Southern Regional Laboratory | 03/28/2025 | 09/08/2025 | No | ||||
| 2025-03-24-35-8 | AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles) | David Padilla, CT D08 - Fontana Southern Regional Laboratory | 04/01/2025 | 09/08/2025 | No | ||||
| 2025-03-24-35-9 | AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles) | David Padilla, CT D08 - Fontana Southern Regional Laboratory | 04/01/2025 | 09/08/2025 | No | ||||
| 2025-03-24-35-10 | ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles) | David Padilla, CT D08 - Fontana Southern Regional Laboratory | 04/01/2025 | 09/08/2025 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-03-24-35-1 AASHTO T27-14
DIME Test ID: 2025-03-24-35-4 AASHTO T84-14
DIME Test ID: 2025-03-24-35-5 AASHTO T85-13
DIME Test ID: 2025-03-24-35-6 AASHTO T96-02r10
DIME Test ID: 2025-03-24-35-7 AASHTO T176-08
DIME Test ID: 2025-03-24-35-8 AASHTO T304-11
DIME Test ID: 2025-03-24-35-9 AASHTO T335-09r13
DIME Test ID: 2025-03-24-35-10 ASTM D4791-10