Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2024-10-28-77

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994084
DEA: 060U8804
EFIS: 0616000074
DIST-CO-RTE-PM06-TUL-99-26.3/27.6
Award Date01/23/2023
Closeout DateNot set
Work DescriptionCONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY
Location DescriptionON STATE ROUTE 99
QA Service Level1 (Verified on 03/13/2023)

Sample Information

Sample Taken Date10/28/2024 Sample Unique Key77
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/29/2024
Sample typeQuality Control A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byJulian Last name of sampler or witnessed byCarmona
Title of samplerQC Field Technician Telephone number of sampler
Laboratory sample identificationMix 180412, Set 1 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCalPortland Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure nameAbutment 1 Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number180412
The truck number from where the sample was collectedLoad 8 The batch plant ticket number from where the sample was collected0
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedAbutment Wall 3 Where the material sample would have been placed if not sampledUnknown
From Lot No.1 Bag Lot No.1

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-10-28-77-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteJulian Carmona, G3 Quality, Incorporated - Cerritos10/28/202403/21/2025
Yes
03/21/2025Public - Test Data Visible
2024-10-28-77-2CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteJulian Carmona, G3 Quality, Incorporated - Cerritos10/28/202403/21/2025
Yes
03/21/2025Public - Test Data Visible
2024-10-28-77-3CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodJulian Carmona, G3 Quality, Incorporated - Cerritos10/28/202403/21/2025
Yes
03/21/2025Public - Test Data Visible
2024-10-28-77-4CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement ConcreteJulian Carmona, G3 Quality, Incorporated - Cerritos10/28/202403/21/2025
Yes
03/21/2025Public - Test Data Visible
2024-10-28-77-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMichael Kaus, G3 Quality, Incorporated - Cerritos11/04/202403/21/2025
Yes
03/21/2025Public - Test Data Visible
2024-10-28-77-6CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMichael Kaus, G3 Quality, Incorporated - Cerritos11/25/202403/21/2025
Yes
03/21/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-10-28-77-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2024-10-28-77-2 CTM 518-June 2010 (Verified)
DIME Test ID: 2024-10-28-77-3 CTM 504-June 2010 (Verified)
DIME Test ID: 2024-10-28-77-4 CTM 556-January 2018 (Verified)
DIME Test ID: 2024-10-28-77-5 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-10-28-77-6 CTM 521-June 2020 (Verified)